Volcengine Direct Connect Configuration
The Volcengine side of the setup: accept the shared connection, create the DC gateway and virtual interface, attach it to a CEN, and bring up BGP.
Background Information
Volcengine Direct Connect (DC) builds a fast, low-latency, stable, and secure private channel between your on-premises data center and your VPCs. Compared with a VPN or public IP addresses, it offers more bandwidth, lower latency, and privacy, and lets one site reach several VPCs over the private network.
A direct connection has four components: the access point, the physical connection, the DC gateway, and the virtual interface. The physical connection links your data center to the access point, the DC gateway is the entry point in the cloud, the virtual interface ties the two together, and a Cloud Enterprise Network (CEN) carries traffic to the VPC.

The shared connection model
Volcengine offers dedicated and shared connections. Going through Zenlayer uses the shared model: Zenlayer has already reached the Volcengine access point as an operator and created the shared physical connection, so you do not arrange a circuit from your site to the access point yourself — you only need to reach the Zenlayer access point. Provisioning is therefore faster and cheaper.
Terminology
Access point
The location where a physical connection reaches Volcengine
Physical connection
The circuit between your facility and the Volcengine access point
DC gateway
The access router for the connection — the entry point from your site into the cloud
Virtual interface (VIF)
The logical interface that ties the physical connection to the DC gateway; supports static and BGP routing
CEN (Cloud Enterprise Network)
The service that interconnects VPCs across regions and links cloud and on-premises networks
VPC
The isolated virtual network you configure for your cloud resources
ASN
The DC gateway's ASN defaults to 137718; the BGP peer ASN must differ from it
VLAN ID
The VLAN of the virtual interface, from 0 to 2999; it must be unique per switch
The definitions follow the Volcengine Direct Connect documentation.
Procedures
The Volcengine-side setup runs as follows:

Before you start
Make sure your Volcengine account has completed real-name verification and that the balance plus vouchers is not below zero.
Create the VPC and subnets you want to reach. Their CIDR blocks must not overlap or conflict with your on-premises network.
Create a CEN instance and attach that VPC to it as a network instance.
Agree the access point, port speed, bandwidth, and high-availability design with your Zenlayer solutions engineer, including the VLAN ID and the interconnect IP plan.
Note
Pick the access point closest to your data center — the shorter the distance, the lower the latency. Access points differ in which carriers and port speeds they support, so confirm with Zenlayer before planning.
Get the shared physical connection
Send Zenlayer your Volcengine account ID and the region you want to reach.
Once Zenlayer creates the shared physical connection, it appears in the Physical Connections list on the Volcengine console awaiting your confirmation (named something like
DAS201_port01_conn).Confirm and accept it, and note its name and project — you select it when creating the virtual interface.
Note
When you terminate the service, delete this shared physical connection as well, or port charges continue.
Create the DC gateway
Open the DC gateway console, select the same region as the physical connection, and click Create DC Gateway:
Region
Must match the physical connection
North China 2 (Beijing)
Name
The gateway's name
dcgw-01
ASN
The gateway's autonomous system number; the Volcengine ASN can be used as is
137718
IPv6
Whether to enable IPv6
Disabled
Project
The project the gateway belongs to
Project-test
Note
A virtual interface can use IPv6 only if IPv6 is enabled on its DC gateway, and that cannot be switched off again. Leave it disabled unless you need it.
Create the virtual interface
Open the virtual interface console, select the same region as the connection and the gateway, and click Create Virtual Interface:
Region
Must match the connection and the gateway
North China 2 (Beijing)
Name
The interface's name
VIF-01
Physical connection
Filter by project to find the connection
Project-test|DAS201_port01_conn
DC gateway
Filter by project to find the gateway
Project-test|dcgw-01
Bandwidth limit
Whether to cap the bandwidth
Off
IPv4 interconnect IPs
The local (cloud gateway) and remote (on-premises gateway) addresses, in the same subnet and distinct
Local 10.0.0.1/30, remote 10.0.0.2/30
VLAN ID
The VLAN towards your site, from 0 to 2999
10
Routing type
BGP (recommended) or static
BGP
BGP peer ASN
From 1 to 4294960000, and different from the gateway ASN
Provided by Zenlayer
BGP key
6 to 80 characters; cannot be changed afterwards
Provided by Zenlayer
Health detection
BGP routing supports BFD
BFD
Note
VLAN ID 0 means the switch port runs as a Layer 3 routed interface, so the connection carries exactly one untagged virtual interface; 1–2999 means Layer 3 subinterfaces, and one connection can carry several virtual interfaces.
The BGP key is sensitive and cannot be changed after creation — store it safely.
If the physical connection needs a QoS policy, do not enable the bandwidth limit on the virtual interface.
Attach the gateway to the CEN
Once the virtual interface exists, attach the DC gateway to the Cloud Enterprise Network so that it can reach the VPC over the private network.
Open the CEN console, select the target instance, and go to the Network Instances tab.
Click Attach Network Instance, choose DC gateway as the type, and select the gateway you created.
Confirm the gateway becomes available and that the VPC is attached to the same CEN.
For cross-region traffic, configure a bandwidth package and the cross-region bandwidth in the CEN.
Route on your side and verify
With static routing, add a route towards your on-premises network on the DC gateway's Routes tab. With BGP routing configured on the virtual interface, routes are learned automatically.
On your switch or router, configure routes towards the VPC CIDR as planned.
On the Volcengine console, check that the virtual interface and the BGP peer show as established.
From a server in your data center, ping the private IP of an ECS instance in the VPC.
For a redundant pair, enable BFD and confirm the failover time meets your expectation.
Note
End-to-end testing is done together with Zenlayer. If connectivity fails, check the VLAN ID, the interconnect subnets, the BGP ASN and key, and the CEN routing in that order.
References
Last updated